Mon - Fri 8:00 AM to 5:00 PM ET     

RF MRI Doors

Air Seal MRI Room Door

Discover unparalleled performance and quality with Gaven’s Failsafe Air Seal MRI Room Door – a crucial solution for the protection of MRI rooms against powerful magnetic fields, radio frequencies, and electronic device interference. The Failsafe MRI series doors redefine standards, providing over 100 dB of attenuation across frequencies up to 1 GHz, specifically optimized for top-notch Radio Frequency (RF) performance.

Available in both single-leaf and double-leaf configurations, each RF-shielded door boasts a robust design. Our doors feature an advanced pneumatically operated and patented shielded air seal system for seamless operation and a consistently precise seal with every cycle. Enhance your MRI environments with the failsafe Air Seal MRI Room Door, setting the benchmark for innovation and reliability.

Previous slide
Next slide
Standard Features:
  • Easy-open handle
  • Push paddle open and close
  • Flush threshold
  • Discreet seals
  • Automatic air seal operation
  • Available in RF-shielded and acoustic configurations
  • Single or double door
  • Heavy-duty Roton™ hinge
  • Works with both existing facilities and new construction
  • Multiple veneer and finish options
  • IV pass-thru

Download Data Sheet >

Standard Sizing:
  • MIL-STD 188-125 Compliance: Designed and rigorously tested to surpass MIL-STD 188-125-1
  • Unmatched Industry Performance: Considered the industry’s top performer due to its exceptional shielding capabilities and best-in-class manufacturing.
  • 304 Stainless Steel Construction: Robust 304 stainless steel construction ensures durability, optimal shielding effectiveness, and corrosion resistance.
  • Optimized Sealing: Fully welded seams for maximum shielding effectiveness, setting it apart from competitors’ aluminum or brass doors.
  • Low Maintenance: Easy to operate and requires minimal maintenance, offering convenience and long-term cost efficiency.
Custom Size & Configurations
  • Bi-parting sliding doors
  • Dual-leaf swing doors
  • Offset side swing doors
Optional Accessories
  • Windows up to 24” x 24”
  • RFID operator
  • Magnetic lock
  • Keypad
  • Blow-out panel
  • Automatic open/close operator

Download Data Sheet >

Applications
  • MRI Room / Medical Imaging Environments

Download Data Sheet >

Ordering Information

Tailor your security with Gaven’s Air Seal MRI Room Doors. Explore customizable options to suit your unique needs or chat with us to request pricing and discuss features that align with your project’s requirements.

Ask an Expert

Want help selecting the right product or just have a question? Ask our team of experts. Fill out the form and we will contact you shortly.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Request a Call

Want help selecting the right product or just have a question? Ask our team of experts. Fill out the form and we will contact you shortly.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Request a Quote

Max. file size: 128 MB.
This field is for validation purposes and should be left unchanged.

Refer to the attenuation characteristics charts to determine what material and cell size are right for your application.

Angle Frame:

  • This construction method typically involves a frame made of angled metal sections.
  • The frame is attached to the structure of the shielded enclosure, providing support for the waveguide material.
  • Angle frame construction is often used for installations where a rigid frame is required to maintain the shape and integrity of the waveguide panels.

Ducted:

  • Ducted waveguides are designed with a duct-like structure, allowing airflow to pass through the interior of the waveguide.
  • This construction method provides a pathway for air to flow while maintaining EMI/RFI shielding integrity.
  • Ducted waveguides are commonly used in HVAC systems where maintaining airflow is crucial, such as in data centers or industrial settings.

Ducted w/ Man Bars (Secure):

  • Ducted waveguides with man bars incorporate additional metal bars or grilles within the duct structure.
  • These man bars help to reinforce the waveguide and provide additional support for the ducted airflow.
  • This construction method is suitable for applications where increased structural integrity and security are required, such as in high-security environments or specialized industrial applications.

Download Failsafe MRI Air Seal Door Data Sheet

Fill out the form below to access or download the Failsafe MRI Air Seal Doors data sheet.

Download Data Center Cabinet Data Sheet

Fill out the form below to access or download the Download the Data Center Cabinet data sheet.

Download HEMP Shielded ISO Storage Containers Data Sheet

Fill out the form below to access or download the HEMP Shielded ISO Storage Containers data sheet

Download EMI Door Data Sheet

Fill out the form below to access or download the EMI Door data sheet.

Download Waveguides PoE Protections Data Sheet

Fill out the form below to access or download the Waveguides PoE Protections data sheet.

Download HEMP Door Data Sheet

Fill out the form below to access or download the HEMP Door data sheet.